FISHER SCIENTIFIC -- AGAR, S71613 -- -
=====================  Product Identification  =====================

Product ID:AGAR, S71613
MSDS Date:12/12/1997
FSC:NIIN:Submitter:N EN
Status Code:A
=== Responsible Party ===
Company Name:FISHER SCIENTIFIC
Address:ONE REAGENT LANE
City:FAIRLAWN
State:NJ
ZIP:07410
Country:US
Info Phone Num:201-796-7100
Emergency Phone Num:201-796-7100
Chemtrec Ind/Phone:(800)424-9300
CAGE:1B464
=== Contractor Identification ===
Company Name:FISHER SCIENTIFIC CO.  CHEMICAL MFG DIV
Address:1 REAGENT LANE
Box:City:FAIRLAWN
State:NJ
ZIP:07410-2802
Country:US
Phone:201-796-7100
CAGE:1B464

=============  Composition/Information on Ingredients  =============

Ingred Name:AGAR  LD50: (ORAL, RAT) 11 G/KG(EINECS/ELINCS: 232-658-1)
CAS:9002-18-0
RTECS #:AW7950000
= Wt:100.

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE INGREDIENT
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYE: DUST MAY CAUSE MECHANICAL
    IRRITATION. SKIN: MAY CAUSE SKIN IRRITATION. LOW HAZARD FOR USUAL
    INDUSTRIAL HANDLING. INGESTION: INGESTION OF LARGE AMOUNTS MAY
    CAUSE GASTROINTESTINAL IRRITATION. EXPEC TED TO BE A LOW INGESTION
    HAZARD. INHALATION: MAY CAUSE RESPIRATORY TRACT IRRITATION. LOW
    HAZARD FOR USUAL INDUSTRIAL HANDLING. CHRONIC: NO INFORMATION
    FOUND. TARGET ORGANS: NONE.
Effects of Overexposure:SEE HEALTH HAZARDS.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH EYES W/PLENTY OF WATER FOR AT LEAST 15 MIN,
    OCCASIONALLY LIFTING UPPER & LOWE LIDS. GET MED AID. SKIN: FLUSH
    SKIN W/PLENTY OF SOAP & WATER FOR AT LEAST 15 MIN WHILE REMOVING
    CONTAM CLTHG &  SHOES. GET MED AID IF IRRIT DEVELOPS OR PERSISTS.
    INGEST: IF VICTIM IS CONSCIOUS & ALERT, GIVE 2-4 CUPFULS OF MILK OR
    WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCON PERSON. GET MED
    AID. INHAL: REMOV E FROM EXPOS TO FRESH AIR IMMED. IF NOT BRTHG,
    GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYGEN. GET MED AID IF
    COUGH OR OTHER SYMPS APPEAR. NOTES TO MD: TREAT SYMPTOMATICALLY &
    SUPPORTIVELY. ANTIDOTE:  NONE REPORTED.

=====================  Fire Fighting Measures  =====================

Flash Point:NOT AVAILABLE
Lower Limits:NOT AVAIL
Upper Limits:NOT AVAIL
Extinguishing Media:FOR SMALL FIRES, USE WATER SPRAY, DRY CHEMICAL,
    CARBON DIOXIDE OR CHEMICAL FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS MATERIAL IN SUFFICIENT QUANTITY AND
    REDUCED PARTICLE SIZE IS CAPABLE OF CREATING A DUST EXPLOSION. NFPA
    RATING: NOT PUBLISHED.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE PROPER PERSONAL PROTECTIVE EQUIPMENT AS
    INDICATED IN SECTION 8, EXPOSURE CONTROLS PERSONAL PROTECTION.
    VACUUM OR SWEEP UP MATERIAL AND PLACE INTO A SUITABLE DISPOSAL
    CONTAINER. AVOID GENERATING DU STY CONDITIONS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE WITH ADEQUATE VENTILATION. AVOID
    CONTACT WITH SKIN AND EYES. AVOID INGESTION AND INHALATION. KEEP
    FROM CONTACT WITH OXIDIZING MATERIALS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:FOLLOW THE OSHA RESPIRATOR REGULATIONS FOUND IN
    29 CFR 1910.134 OR EUROPEAN STANDARD EN 149. ALWAYS USE A NIOSH OR
    EUROPEAN STANDARD EN 149 APPROVED RESPIRATOR WHEN NECESSARY.
Ventilation:USE ADEQUATE VENTILATION TO KEEP AIRBORNE CONCENTRATIONS
    LOW.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH AND DELUGE SHOWER .
    WEAR APPROPRIATE PROTECTIVE CLOTHING TO MINIMIZE CONTACT WITH SKIN.
Supplemental Safety and Health
EXPOSURE LIMITS: AGAR - ACGIH: NONE LISTED. NIOSH: NONE LISTED. OSHA -
    FINAL PELS: NONE LISTED. OSHA VACATED PELS: AGAR: NO OSHA VACATED
    PELS ARE LISTED FOR THIS CHEMICAL. PHYSICAL DATA: MOLECULAR FOR
    MULA: NOT AVAILABLE.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:NOT AVAILABLE
Melt/Freeze Pt:=0.C, 32.F
Decomp Temp:Decomp Text:NOT AVAILABLE
Vapor Pres:NEGLIGIBLE
Vapor Density:NOT AVAIL
Spec Gravity:NOT AVAILABLE
pH:NOT AVAILABLE
Viscosity:NOT AVAILABLE
Solubility in Water:SOLUBLE IN HOT WATER
Appearance and Odor:LIGHT BEIGE SOLID; ODORLESS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:STRONG OXIDANTS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

===================  Toxicological Information	===================

Toxicological Information:CAS #9002-18-0: ORAL, MOUSE: LD50 = 16 G/KG;
    ORAL, RABBIT: LD50 = 5800 GM/KG. CARCINOGENICITY: CAS #9002-18-0:
    NOT LISTED BY ACGIH, IARC, NIOSH, NTP OR OSHA. EPIDEMIOLOGY: NOT
    DATA AVAILABLE. TERATOGE NICITY: NO DATA AVAILABLE. REPRODUCTIVE
    EFFECTS: NO DATA AVAILABLE. NEUROTOXICITY: NO DATA AVAILABLE.
    MUTAGENICITY: NO DATA AVAILABLE. OTHER STUDIES: NO DATA AVAILABLE.

=====================  Ecological Information  =====================

Ecological:EXOTOXICITY: NOT AVAILABLE. ENVIRONMENTAL FATE: NOT
    AVAILABLE. PHYSICAL/CHEMICAL: NOT AVAILABLE. OTHER: NOT AVAILABLE.
    OTHER INFO: HAZARD SYMBOLS: NOT AVAILABLE. WGK (WATER
    DANGER/PROTECTION) CAS #900 2-18-0: 0. CANADA - CAS #9002-18-0 IS
    LISTED ON CANADA'S DSL/NDSL LIST. THIS PRODUCT HAS A WHMIS
    CLASSIFICATION OF NOT CONTROLLED. CAS #9002-18-0 IS NOT LISTED ON
    CANADA'S INGREDIENT DISCLOSURE LIST.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN A MANNER CONSISTENT WITH FEDERAL,
    STATE AND LOCAL REGULATIONS. RCRA D-SERIES MAXIMUM CONCENTRTION OF
    CONTAMINANTS: NONE LISTED. RCRA D-SERIES CHRONIC TOXICITY REFERENCE
    LEVELS: NONE LIST ED. RCRA F-SERIES: NONE LISTED. RCRA P-SERIES:
    NONE LISTED. RCRA U-SERIES: NONE LISTED.

===================  MSDS Transport Information  ===================

Transport Information:US DOT: NO INFORMATION AVAILABLE. IATA: NOT
    REGULATED AS A HAZARDOUS MATERIAL. RID/ADR: NOT REGULATED AS A
    HAZARDOUS MATERIAL. IMO: NOT REGULATED AS A HAZARDOUS MATERIAL.
    CANADA TDG: NO INFORMATION AV AILABLE.

=====================  Regulatory Information  =====================

SARA Title III Information:SECTION 302 (RQ): NONE OF THE CHEMICALS IN
    THIS MATERIAL HAVE AN RQ. SECTION 302 (TPQ): NONE OF THE CHEMICALS
    IN THIS PRODUCT HAVE A TPQ. SECTION 313: NO CHEMICALS ARE
    REPORTABLE UNDER SECTION 313.
Federal Regulatory Information:CAS #9002-18-0 IS LISTED ON THE TSCA
    INVENTORY. NONE OF THE CHEMICALS ARE ON THE HEALTH & SAFETY
    REPORTING LIST. NONE OF THE CHEMICALS IN THIS PRODUCT ARE UNDER A
    CHEMICAL TEST RULE. NONE OF THE CHEMI CALS ARE LISTED UNDER TSCA
    SECTION 12B. TSCA SIGNIFICANT NEW USE RULE: NONE OF THE CHEMICALS
    IN THIS MATERIAL HAVE A SNUR UNDER TSCA. CLEAN AIR ACT: THIS
    MATERIAL DOES NOT CONTAIN ANY HAZARDOUS AIR PO LLUTANTS. THIS
    MATERIAL DOES NOT CONTAIN ANY CLASS 1 OZONE DEPLETORS. THIS
    MATERIAL DOES NOT CONTAIN  ANY CLASS 2 OZONE DEPLETORS. CLEAN WATER
    ACT: NONE OF THE CHEMICALS IN THIS PRODUCT ARE LISTED AS (OTHER
    INFO)
State Regulatory Information:CAS #9002-18-0 IS NOT PRESENT ON STATE
    LISTS FROM CA, PA, MN, MA, FL, OR NJ. CALIFORNIA NO SIGNIFICANT
    RISK LEVEL: NONE OF THE CHEMICALS IN THIS PRODUCT ARE LISTED.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.