CHEM SERVICE INC -- PHOSPHOMOLYBDIC ACID, I-85 -- 6810-00N067493
=====================  Product Identification  =====================

Product ID:PHOSPHOMOLYBDIC ACID, I-85
MSDS Date:09/01/1988
FSC:6810
NIIN:00N067493
=== Responsible Party ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Info Phone Num:215-692-3026
Emergency Phone Num:215-692-3026
CAGE:84898
=== Contractor Identification ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Phone:215-692-3026
CAGE:84898
Company Name:CHEM SERVICE, INC
Address:660 TOWER LN
Box:599
City:WEST CHESTER
State:PA
ZIP:19301-9650
Country:US
Phone:610-692-3026
CAGE:8Y898

=============  Composition/Information on Ingredients  =============

Ingred Name:PHOSPHOMOLYBDIC ACID, HYDRATE; (PHOSPHOMOLYBDIC ACID)
CAS:51429-74-4
OSHA PEL:5 MG/M3 (MFR)
ACGIH TLV:5 MG/M3 (MFR)

Ingred Name:SUPDAT: REMOVE & WASH CONTAMD CLTHG. DO NOT WEAR
    SHOES/CLTHG UNTIL ABSOLUTELY FREE OF ALL CHEM ODORS. DO NOT (ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2: ADMIN LIQS/INDUCE VOMIT TO UNCON OR CONVULSING
    PERSON. IF SWALLOWED DRINK 1 TO 2 GLASSES OF WATER. IF (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3: SWALLOWED DO NOT INDUCE VOMIT. CONTACT POIS CTL CTR
    IMMED IF NEC. GET MED ATTN IF NEC. IF VOMITING-WATCH (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4: CLOSELY TO MAKE SURE AIRWAY DOES NOT BECOME
    OBSTRUCTED BY VOMIT.
RTECS #:9999999ZZ

Ingred Name:EYE PROT: AND FULL LENGTH FACESHIELD .
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ALL CHEMS SHOULD BE CONSIDERED HAZ -
    AVOID DIRECT PHYSICAL CONTACT! VAPORS &/OR DIRECT EYE CONTACT CAN
    CAUSE SEV EYE BURNS. CAN CAUSE SKIN BURNS. RPTD EXPOS TO VAPORS
    &/OR DUST CAN CAUSE EYE INJURY. C AN BE HARMFUL IF INHALED. DUST
    &/OR VAPORS CAN CAUSE IRRIT TO RESP TRACT. CAN BE HARMFUL IF
    SWALLOWED. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CAN CAUSE GI DISTURBANCES. POSSIBLE
    CHOLINESTERASE INHIBITOR - MAY CAUSE SEIZURES, NAUS, VOMIT, AIRWAY
    OBSTRUCTION &/OR INCREASED MUCOUS SECRETIONS IN THE LUNGS. INGEST
    MAY CAUSE SEV CORR OF  MOUTH. INGEST MAY CAUSE SEV CORR OF GITRACT.
    CAN BE IRRITATING TO MUCOUS MEMBRANES. INGESTION MAY CAUSE
    DIARRHEA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF POIS. IT
    SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE CAN BE
    OBTAINED FROM POIS CTL CTR. EYES: FLUSH CONTINUOUSLY W/WATER FOR AT
    LEAST 1 5-20 MIN. SKIN: FLUSH SKIN W/WATER FOR 15-20 MIN. IF NO
    BURNS HAVE OCCURRED-USE SOAP & WATER TO CLEANSE SKIN. INHAL: REMOVE
    TO FRESH AIR. ADMIN OXYGEN IF HAVING DFCLTY BRTHG. IF BRTHG HAS
    (SUPDAT)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL POWDER. DO NOT USE
    WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
    EQUIPMENT. VENTILATE AREA. SWEEP UP AND PLACE IN AN APPROPRIATE
    CONTAINER. HOLD FOR DISPOSAL. WASH CONTAMINATED SURFACES TO REMOVE
    ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES AND
    CLOTHING. KEEP TIGHTLY CLOSED AND STORE IN A COOL, DRY PLACE. STORE
    ONLY WITH COMPATIBLE CHEMICALS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
    NOT HANDLE THIS CHEMICAL OR ITS CNTNR. PROD IS FURNISHED FOR LAB
    USE ONLY! PRODS MAY NOT BE USED AS DRUGS, COSMETICS, AGRICULTURAL
    OR PESTICIDAL PROD UCTS, FOOD ADDITIVES OR HOUSEHOLD CHEMS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 6)
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . USE
    APPROPRIATE OSHA/MSHA APPROVED SAFETY EQUIPMENT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
    LABORATORY.
Supplemental Safety and Health
MATL TO AVOID: THIONYL CHLORIDE. REACTS W/CARBONATES. INCOMPAT W/IRON &
    ZINC & OTHER LIGHT METALS. FIRST AID PROC: STOPPED ADMIN ARTF RESP.
    IF EXHIBITING SIGNS OF SHOCK - KEEP WARM & QUIET. GET MED AT TN IF
    NEC. IF IN CARD ARREST ADMIN CPR.CONTINUE LIFE SUPPORTING MEASURES
    UNTIL MED ASSISTANCE HAS ARRIVED. (ING 2)

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:>172F,>78C
Solubility in Water:SOLUBLE
Appearance and Odor:YELLOW CRYSTALLINE SOLID.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
REACTS W/ADIC HALIDES & ANHYDRIDES. CORR. REACTS W/PHOSPHORUS HALIDES.
    INCOMPAT W/STRONG BASES. REACTS WITH (SUPDAT)
Stability Condition to Avoid:DO NOT USE MAGNESIUM/ALUMINUM OR THEIR
    ALLOYS AS CNTNRS. CORRODES STEEL. CORRODES COPPER & ITS ALLOYS.
Hazardous Decomposition Products:DECOMPOSITION LIBERATES TOXIC FUMES.
    DECOMPOSES UNDER ALKALINE CONDITIONS. DECOMPOSITION PRODUCTS ARE
    CORROSIVE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
    STATE AND LOCAL REGULATIONS . DISPOSE OF IN AN APPROVED CHEMICAL
    LANDFILL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.