ANACHEMIA CHEMICALS INC -- HYDROCHLORIC ACID 5-<10% -- 6810-00N069193
=====================  Product Identification  =====================

Product ID:HYDROCHLORIC ACID 5-<10%
MSDS Date:03/09/1994
FSC:6810
NIIN:00N069193
=== Responsible Party ===
Company Name:ANACHEMIA CHEMICALS INC
Address:3 LINCOLN BLVD
City:ROUSES POINT
State:NY
ZIP:12079
Country:US
Info Phone Num:518-297-4444
Emergency Phone Num:518-297-4444;800-424-9300(CHEMTREC)
CAGE:4A444
=== Contractor Identification ===
Company Name:ANACHEMIA CHEMICALS INC
Box:UNKNOW
CAGE:3A444
Company Name:ANACHEMIA CHEMICALS INC
Address:3 LINCOLN BLVD
Box:City:ROUSES POINT
State:NY
ZIP:12979
Country:US
Phone:518-297-4444
CAGE:4A444

=============  Composition/Information on Ingredients  =============

Ingred Name:HYDROCHLORIC ACID  (SARA 302/313) (CERCLA)
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: 5-<10%
OSHA PEL:5 PPM, C
ACGIH TLV:5 PPM, C
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: BALANCE
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT:SILICIDES, HYDROXIDES, PROPYLENE OXIDE, FLUORINE,
    WATER REACTIVE MATLS, SILVER PERCHLORATE, CARBON (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3:TETRACHLORIDE, PERCHLORIC ACID, 2-AMINOETHANOL,
    AMMONIUM HYDROXIDE, ETHYLENEDIAMINE, ETHYLENEIMINE, OLEUM, (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4:COPPER & ALUMINUM & THEIR ALLOYS, ALKALI METALS,
    SULFITES.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP:VOMIT. CAN CAUSE LUNG DMG. INGEST:BURNS IN
    MOUTH, PHARYNX & GI TRACT. WEAK FROM FALLING BLOOD (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:PRESS, NAUS, VOMIT, DYSPHAGIA, ABDOM PAIN, CVS
    COLLAPSE, CONVLS, COMA & DEATH POSS. ASPHYXIA MAY OCCUR FROM(ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:EDEMA OF GLOTTIS. CHRONIC:EROSION OF TEETH,
    ULCERATION OF NOSE, MOUTH & GUMS, BRONCH. RPTD/PRLNG SKIN CONT (ING
    9)
RTECS #:9999999ZZ

Ingred Name:ING 8:MAY CAUSE DERM. TARGET ORGS:SKIN, EYES, LUNGS, RESP
    SYS. TO BEST OF MFR'S KNOWLEGDE, CHEM, PHYSICAL & TOX (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:OF THIS SUBSTANCE HAS NOT BEEN FULLY INVESTIGATED.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:ARTICLES SUCH AS SHOES & BELTS. INHAL:REMOVE
    PATIENT TO FRESH AIR. ADMIN APPRVD OXYG SUPPLY IF (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:BRTHG IS DFCLT. ADMIN ARTF RESP/CPR IF BRTHG HAS
    CEASED. CALL MD. INGEST:IF CONSCIOUS, WASH OUT MOUTH W/ (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:WATER. HAVE CONSCIOUS PERS DRINK SEVERAL GLASSES OF
    WATER/MILK, REPEATING IF VOMIT. DO NOT INDUCE VOMIT. (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:AIM TO DILUTE ACID 100 TIMES APPROX. SEEK IMMED MED
    ATTN. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:COMPLETE. DO NOT EMPTY INTO DRAINS. DO NOT TOUCH
    SPILLED MATERIAL.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:DRY. MANIPULATE UNDER ADEQ FUME HOOD. MAY
    CORRODE METALLIC SURFS. PROT FROM MOISTURE. DO NOT USE (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:PRESS TO DISPENSE. EMPTY CNTNRS MAY CONTAIN HAZ
    RESIDUE. HANDLE & OPEN CNTNR W/CARE. DO NOT GET IN EYES, (ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:ON SKIN/ON CLTHG. I/A/W GOOD STOR & HNDLG PRACTICES.
    DO NOT ALLOW SMOKING & FOOD CONSUMPTION WHILE HNDLG.(ING 19)
RTECS #:9999999ZZ

Ingred Name:ING 18:FOR LAB USE ONLY.
RTECS #:9999999ZZ

Ingred Name:EYE PROT:& FULL LENGTH FACESHIELD .
RTECS #:9999999ZZ

Ingred Name:OTHER PROT EQUIP:CLTHG AS REQD FOR WORKPLACE CNDTNS TO PVNT
    CONT W/HYDROCHLORIC ACID SOLNS. SUFFICIENT TO PROT (ING 22)
RTECS #:9999999ZZ

Ingred Name:ING 21:SKIN. HAVE AVAIL & USE AS APPROPRIATE: SUITS, APRONS
    & BOOTS.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:VAPS, LIQS & MISTS ARE
    EXTREMELY CORR. BRIEF CONT OF VAPS WILL BE SEVERELY IRRIT. BRIEF
    CONT OF LIQ/MIST WILL SEVERELY DMG & PRLNG CONT MAY CAUSE PERM
    INJURY WHICH MAY BE FOLLOWED BY BLINDNE SS. SKIN:CAUSES SEV BURNS.
    SEV PAIN & BROWNISH/YELLOW STAINS:USUALLY PENETRATES FULL THICKNESS
    OF SKIN.(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:LESSER EXPOS MAY CAUSE DERM &
    PHOTOSENSIT. INHAL:MATL IS EXTREMELY DESTRUCT TO TISS OF MUC MEMBS
    & UPPER RESP TRACT. INHAL MAY BE FATAL AS RSLT OF SPASM, INFLAMM &
    EDEMA OF LARYNX & BRONCHI,	CHEM PNEUM & PULM EDEMA. SYMPS OF
    EXPOSMAY INCL BURNING SENSATION, COUGH, LARYNGITIS, DYSPNEA, HDCH,
    NAUS & (ING 6)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE:IMMED FLUSH W/COPIOUS QTYS OF WATER FOR AT LST 30 MINS
    HOLDING LIDS APART TO ENSURE FLUSHING OF ENTIRE SURF. DO NOT USE
    CHEM ANTIDOTES. SPEED IS ESSNTL. SEEK IMMED MED ATTN. SKIN:IMMED
    FLUSH W/PLE NTY OF WATER FOR AT LST 30 MINS WHILE REMOVING CONTAM
    CLTHG & SHOES. DO NOT USE CHEM ANTIDOTES. SPEED IS ESSNTL. SEEK
    IMMED MED ATTN. WASH CONTAM CLTHG BEFORE REUSING. DISCARD CONTAM
    LEATHER (ING 11)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING
    MATERIALS.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
    COOL CNTNG VESSELS W/FLOODING QTYS OF WATER UNTIL WELL AFTER FIRE
    IS OUT. DO NOT GET WATER INSIDE CNTNR.
Unusual Fire/Explosion Hazard:FLAMMABLE/EXPLOSIVE HYDROCARBON GAS MAY
    BE FORMED UPON CONTACT OF THIS PRODUCT W/METALS. EMITS TOXIC FUMES
    UNDER FIRE CONDITIONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR NIOSH/MSHA APPRVD SCBA, RUB BOOTS & HEAVY
    RUB GLOVES. FULL SUIT. EVACUATE & VENT AREA. COVER W/SODA ASH/LIME.
    THIS WILL RELS CARBON DIOXIDE, SO USE CAUT. PLACE IN SUITABLE CNTNR
    & MARK FOR DISP.  WASH SPILL SITE AFTER MATL PICK UP IS (ING 15)
Neutralizing Agent:SODA ASH OR LIME.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL PLACE AWAY FROM HEATED
    AREAS, SPKS & FLAME. STORE IN WELL VENTED AREA. STORE AWAY FROM
    INCOMPAT MATLS. DO NOT WASH DOWN DRAIN.
Other Precautions:DO NOT ADD ANY OTHER MATL TO CNTNR. DO NOT BREATHE
    GAS/FUMES/VAP/SPRAY. IN CASE OF INSUFFICIENT VENT, WEAR SUITABLE
    NIOSH/MSHA APPRVD RESP EQUIP. KEEP AWAY FROM DIRECT SUNLIGHT/STRONG
    INCANDESCENT LIG HT. KEEP CNTNR TIGHTLY CLSD & (ING 16)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQD IF HNDLD IN CLSD VENT SYS. WHERE REQD
    (LEAK, SPILL, OPEN HNDLG OF LIQ) USE NIOSH/MSHA APPRVD CHEM
    CARTRIDGE RESP FOR GAS <60 PPM. FOR GAS >60 PPM/MIST, USE
    NIOSH/MSHA APPRVD SCBA/AIR SUPPLIE D RESP, BOTH W/FULL FACEPIECES.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD TO KEEP AIRBORNE LEVELS
    BELOW RECOMMENDED EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES (NEOPRENE).
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 20)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA. APRON, COVERALLS &/OR OTHER RESIST PROT(ING
    21)
Work Hygienic Practices:WASH WELL AFTER USE. TAKE OFF IMMEDIATELY ALL
    CONTAMINATED CLOTHING. DO NOT WEAR CONTACT LENSES.
Supplemental Safety and Health
PH(1% SOLN/WATER):<7. MATLS TO AVOID:ANHYDRIDE, BETA-PROPIOLACETONE,
    VINYL ACETATE, MERCURIC SULFATE, CALCIUM PHOSPHIDE, FORMALDEHYDE,
    ALKALIES, CARBONATES, BASES, SULFURIC ACID, CHLOROSULFONIC ACID, 
    NITRIC ACID, OXIDIZING AGENTS, CYANIDES, SULFIDES, FLUORIDES,
    PHOSPHIDES, ACETYLIDES, BROMIDES, CARBIDES, (ING 3)

==================  Physical/Chemical Properties  ==================

HCC:T4
Vapor Density:1.3
pH:SUPDAT
Solubility in Water:MISCIBLE
Appearance and Odor:COLORLESS FUMING LIQUID W/PUNGENT ODOR.
Percent Volatiles by Volume:100V/V

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
WILL CORRODE WIDE VARIETY OF METALS. REACTS W/MOST COMMON METALS TO
    PRDCE HYDROGEN. AMINES, METAL OXIDES, ACETIC(SUDPAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FIRE DEGRADATION PRODUCTS: HYDROGEN
    CHLORIDE GAS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
    REGULATIONS . ACCORDING TO ALL APPLICABLE REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.