PARKER PAINT -- WALLGLOW MED BASE, 3800 -- 8010-00N031115
=====================  Product Identification  =====================

Product ID:WALLGLOW MED BASE, 3800
MSDS Date:10/08/1992
FSC:8010
NIIN:00N031115
MSDS Number: CBBSV
=== Responsible Party ===
Company Name:PARKER PAINT
Box:11047
City:TACOMA
State:WA
ZIP:98411-0047
Country:US
Info Phone Num:206-473-1122
Emergency Phone Num:206-473-1122
Preparer's Name:D. FARROW
CAGE:9H480
=== Contractor Identification ===
Company Name:PARKER PAINT
Address:3003 SOUTH TACOMA WAY
Box:11047
City:TACOMA
State:WA
ZIP:98409
Country:US
Phone:253-473-1122
CAGE:9H480

=============  Composition/Information on Ingredients  =============

Ingred Name:SILICA, CRYSTALLINE - QUARTZ; (SILICON DIOXIDE)
CAS:14808-60-7
RTECS #:VV7330000
Fraction by Wt: 1.21%
OSHA PEL:0.1 MG/M3 (MFR)
ACGIH TLV:0.1 MG/M3 RDUST

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVEREXPOSURE MAY CAUSE HEADACHE,
    NAUSEA, SKIN & EYE IRRITATION. INHALATION:INHALATION OF HIGH
    CONCENTRATIONS OF VAPORS MAY CAUSE HEADACHE, NAUSEA & IRRITATION OF
    NOSE, THROAT & LUNGS. EYE CONTAC T:MAY CAUSE IRRITATION OR BURNING.
    SKINCONTACT:REPEATED LIQUID CONTACT MAY CAUSE IRRITATION & DERM.
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
    MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON
    CARCINS, (SUPDAT)
Effects of Overexposure:HLTH HAZ:SKIN ABSORPTION:NONE KNOWN AT THIS
    TIME. INGEST:SWALLOWING CAN CAUSE GI IRRIT, NAUS, VOMIT & DIARR.
    VOMIT CAN RESULT IN ASPIR OF MATL INTO LUNGS WHICH CAN CAUSE CHEM
    PNEUM. CHRONIC:UNPROTECTE D OVEREXP TO MISTS FROM SPRAY APPLICATION
    MAY CAUSE LUNG DISEASE (SILICOSIS).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED, APPLY
    ARTF RESP. CONSULT MD. EYES:WASH W/CLEAN WATER FOR AT LEAST 15
    MINUTES. CONSULT MD. SKIN:WASH AFFECTED AREAS W/SOAP & WATER.
    REMOVE CONTAMINA TED CLOTHING. CONSULT MD. INGEST:DRINK 1-2 GLASSES
    OF WATER TO DILUTE. CONSULT MD OR POISON CONTROL CENTER
    IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:FOAM, ALCOHOL FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY BE USED TO COOL CLOSED
    CONTAINERS TO PREVENT PRESSURE BUILD UP & EXPLOSION WHEN EXPOSED TO
    EXTREME HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. PREVENT SKIN & EYE CONTACT &
    BREATHING OF VAPOR. CONTAIN & REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE ABOVE 200F.
Other Precautions:DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF
    CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT REQUIRED FOR BRUSH & ROLL APPLICATION. FOR
    SPRAY APPLICATION, WEAR A PROPERLY FITTED NIOSH/MSHA (TC-23C)
    APPROVED VAPOR/PARTICULATE RESPIRATOR UNTIL ALL VAPORS & SPRAY MIST
    ARE EXHAUSTED.
Ventilation:PROVIDE SUFFICIENT VENT IN VOL & PATTERN TO KEEP AIR CONTAM
    CONC BELOW APPLIC OSHA PEL/ACGIH TLV OCCUP EXPOS LIMITS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . COVERALLS & HOODS ARE REC DURING
    SPRAY(SUPDAT)
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING THE RESTROOM.
Supplemental Safety and Health
EXPLAN OF CARCIN:1994:ANTICIPATED TO BE CARCINOGEN. OTHER PROT
    EQUIP:APPLICATION. PROTECTIVE CREAMS MAY BE USED FOR EASE OF
    CLEAN-UP, NOT FOR PROTECTION.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Vapor Density:LTR/AIR
Spec Gravity:1.2 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:DILUTABLE
Appearance and Odor:WHITE COLORED LIQUID W/AMMONIACAL ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN AT THIS TIME.
Stability Condition to Avoid:DO NOT HEAT ABOVE 200F.
Hazardous Decomposition Products:NONE KNOWN AT THIS TIME.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
    WATER SYSTEMS. ABSORB LARGE SPILLS W/SAND, CLAY OR DIATOMACEOUS
    EARTH. DISPOSE I/A/W LOCAL, STATE & FEDERAL REQUIREMENTS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.