JOHNSON MATTHEY -- CHROMIUM POWDER, 10148 -- 6810-00N066656
=====================  Product Identification  =====================

Product ID:CHROMIUM POWDER, 10148
MSDS Date:12/06/1988
FSC:6810
NIIN:00N066656
=== Responsible Party ===
Company Name:JOHNSON MATTHEY
Address:30 BOND ST
City:WARD HILL
State:MA
ZIP:01835-0747
Country:US
Info Phone Num:508-521-6300
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:0JVJ1
=== Contractor Identification ===
Company Name:JOHNSON MATTHEY CATALOG CO INC ALFA AESAR
Address:30 BOND ST
Box:City:WARD HILL
State:MA
ZIP:01835-0747
Country:US
Phone:978-521-6300
CAGE:0JVJ1

=============  Composition/Information on Ingredients  =============

Ingred Name:CHROMIUM (SARA 313) (CERCLA)
CAS:7440-47-3
RTECS #:GB4200000
Fraction by Wt: 100%
OSHA PEL:1 MG/M3
ACGIH TLV:0.5 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:CHROMIUM HAS LOW ORAL
    TOX. MAY EFFECT GI & URINARY SYS. SKIN/EYE:POWDER/DUST CAUSES
    IRRIT. INHAL:POWDER/DUST CAUSES IRRIT TO MUC MEMBS & UPPER RESP
    TRACT. MAY CAUSE FIBROSIS. CHRONIC:INGE ST:STOM PAINS, VOMIT,
    DIARR, LIVER & KIDNEY DMG HAVE BEEN REPORTED FROM PRLNGD EXPOS.
    SKIN:PRLNGD EXPOS(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:TO SOME CHROMIUM CMPDS MAY RSLT IN
    SENSIT. EYE:NONE KNOWN. INHAL:FIBROSIS OF LUNGS MAY DEVELOP TO
    PNEUMONCONIOSIS. THERE ARE SOME REFERENCES TO CHROMIUM CAUSING LUNG
    CANCER. OTHER:CHROMIUM I S CONSIDERED CARCINOGENIC BY NTP & IARC.
    TESTING WAS DONE PRIMARILY ON CHROMIUM CMPDS. SINCE SOME CMPDS
    TESTED (SUP DAT)
Medical Cond Aggravated by Exposure:PRE-EXISTING PULMONARY DISEASES.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMED . NO DATA AVAIL BUT ONE SHOULD OBTAIN
    MED ATTN. SKIN:REMOVE CONTAM CLTHG, FLOOD SKIN W/LG AMTS OF WATER.
    EYE:IMMED FLUSH, INCLUDING UNDER EYELIDS, W/LG AMTS OF WATER FOR AT
     LST 15 MIN. CALL MD. INHAL:REMOVE TO FRESH AIR. SUPPORT BRTHG
    (GIVE O*2/ARTIFICIAL RESPIRATION) . NO SPECIFIC INFO AVAIL, ONE
    SHOULD OBTAIN MED ATTN.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:FLAM SOLID IN POWDER FORM. USE WATER SPRAY/FOG, DRY
    CHEM EXTING AGENTS, CARBON DIOXIDE/DRY SAND.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT . IF WITHOUT RISK, REMOVE MATERIAL FROM FIRE
    AREA. COOL CONTAINER WITH WATER FROM MAX DIST.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEARING FULL PROTECTIVE EQUIPMENT, COVER SPILL
    WITH DRY SAND OR VERMICULITE. MIX WELL AND CAREFULLY TRANSFER TO A
    CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
    IN A COOL, DRY, WELL-VENTILATED AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED HIGH EFFICIENCY PARTICLE
    RESPIRATOR.
Ventilation:LABORATORY FUME HOOD.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER . LAB COAT & APRON, FLAME & CHEM RESIST COVERALLS, & (SUP
    DAT)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MATLS TO AVOID:CHLORATE, SO*2, HG, LI. OTHER:POWDERED FORM MAY REACT
    VIOLENTLY W/STRONG OXIDIZERS. RXN W/MINERAL ACIDS MAY EVOLVE H*2
    GAS. EFTS OF OVEREXP:POS, ALL CHROMIUM CNTNING CMPDS & PURE ELEMEN
    T ARE ASSUMED TO BE POTENTIALLY CARCIN.HYGIENE PRACT:HYGIENIC
    FACILITIES FOR WASHING.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:4500F,2482C
Melt/Freeze Pt:M.P/F.P Text:3407F,1875C
Vapor Pres:1 @ 1616C
Spec Gravity:7.19 (H*2O=1)
Evaporation Rate & Reference:0 (BUAC=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:SILVER-GREY IN COLOR, NO ODOR.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACID, OXIDIZERS & ALKALIES. SPECIFIC CMPDS INCLUDE AMMONIUM
    NITRATE, H*2O*2, NITRIC OXIDE, POSTASSIUM (SUPP DATA)
Stability Condition to Avoid:INCOMPATIBLES.
Hazardous Decomposition Products:FLAMMABLE H*2 GAS, TOXIC FUMES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONSULT STATE, LOCAL OR FEDERAL EPA REGULATIONS
    FOR PROPER DISPOSAL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.