KELLY-MOORE PAINT CO INC -- 1240-SERIES (ALL COLORS), ACRY-SHIELD (SUPDAT) -- 8010-00N077083
===================== Product Identification =====================
Product ID:1240-SERIES (ALL COLORS), ACRY-SHIELD (SUPDAT)
MSDS Date:09/21/1994
FSC:8010
NIIN:00N077083
MSDS Number: CDNGV
=== Responsible Party ===
Company Name:KELLY-MOORE PAINT CO INC
Address:1015 COMMERCIAL ST
City:SAN CARLOS
State:CA
ZIP:94070
Country:US
Info Phone Num:415-592-8337
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:0Y837
=== Contractor Identification ===
Company Name:KELLY-MOORE PAINT CO INC
Address:987 COMMERCIAL ST
Box:City:SAN CARLOS
State:CA
ZIP:94070
Country:US
Phone:650-592-8337
CAGE:0Y837
============= Composition/Information on Ingredients =============
Ingred Name:ETHYLENE GLYCOL (SARA 313) (CERCLA) VP: 0.1 @ 68F
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: 2-4%
OSHA PEL:N/K
ACGIH TLV:50 PPM, VAPOR, C
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:SILICA, CRYSTALLINE - CRISTOBALITE; (SILICA, CRYSTALLINE)
(MFR'S CAS # 14464-45-1)
CAS:14464-46-1
RTECS #:VV7325000
Fraction by Wt: 2-5%
OSHA PEL:N/K
ACGIH TLV:0.05 MG/M3 RDUST
Ingred Name:PROPIONIC ACID, 2-METHYL-, MONOESTER WITH
2,2,4-TRIMETHYL-1,3-PENTANEDIOL; (TEXANOL) VP: 0.04 @ 68F
CAS:25265-77-4
RTECS #:UF6000000
Fraction by Wt: 1-2%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ZINC OXIDE (SARA 313) (CERCLA)
CAS:1314-13-2
RTECS #:ZH4810000
Fraction by Wt: 0-2%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
Ingred Name:PIGMENTS (SUCH AS INGREDIENTS 6-8)
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:MINERAL SILICATES
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SILICON DIOXIDE
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS:13463-67-7
RTECS #:XR2275000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
Ingred Name:PAINT PRESERVATIVES CONTAINING INGREDIENTS 10, 11 AND/OR 12
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:4-ISOTHIAZOLIN-3-ONE,5-CHLORO-2-METHYL-
CAS:26172-55-4
RTECS #:NX8156850
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:CARBAMIC ACID, BUTYL-,3-IODO-2-PROPYNYL ESTER
CAS:55406-53-6
RTECS #:EZ0950000
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ANTIMICROBIAL PRESERVATIVE
CAS:26530-20-1
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: DIZZINESS, HEADACHE, NAUSEA,
CONFUSION, IRRITATION TO UPPER RESPIRATORY TRACT, SKIN AND EYE
IRRITATION. CHRONIC: PROLONGED AND/OR REPEATED OVEREXPOSURE TO HIGH
CONCENTRATIONS OF RESPIRABLE (AIR BORNE) CRYSTALLINE SILICA DUSTS
AS MAY BE GENERATED BY SANDING OR GRINDING OF DRIED PAINTS AND
OTHER (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-CRISTOBALITE: IARC
MONOGRAPHS, SUPPLEMENT, VOL 7, PG 341, 1987:GROUP 2A. NTP 7TH
ANNUAL (SUPDAT)
Effects of Overexposure:HLTH HAZ: BUILDING MATERIALS WITHOUT WEARING
PROPER RESPIRATORY PROTECTION CAN CAUSE SILICOSIS, A NON-CANCEROUS
LUNG DISEASE THAT CAN RESULT IN SUBSTANTIAL IMPAIRMENT OF BREATHING
FUNCTION.
Medical Cond Aggravated by Exposure:NONE KNOWN. SEE YOUR MD FOR
SPECIFIC MEDICAL OPINION REGARDING YOUR CONDITION.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. CONSULT
MD. EYES: FLUSH WITH LARGE VOLUMES OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN: WIPE OFF WITH A RAG. WASH
THOROUGHLY WITH SOAP AND WATER. INGESTION: CONSULT HOSPITAL
EMERGENCY ROOM OR POISON CONTROL CENTER IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE (DUE TO THE
BUILDUP OF STEAM PRESSURE) WHEN EXPOSED TO EXTREME HEAT.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA TO PREVENT BUILDUP OF VAPORS.
FOR SMALL SPILLS, SOAK UP WITH ABSORBENT. FOR LARGER SPILLS, DIKE
AREA WITH ABSORBENT MATERIAL AND SCOOP UP LIQUIDS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE UPRIGHT IN SEALED CONTAINERS
AWAY FROM HEAT AND FLAME.
Other Precautions:REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE A NIOSH APPRVD PARTICULATE MASK (TC-21C) TO
AVOID BRTHG SPRAY MIST OR SANDING DUST IF LOCAL VENT IS ADEQ TO
KEEP VAP CONCS W/IN ACCEPTABLE (TLV) LIMITS. IF LOCAL VENT IS NOT
SUFFICIENT OR WHERE EX POSURE LIMITS ARE EXCEEDED, (SUPDAT)
Ventilation:LOCAL CROSS-VENTILATION OR MECHANICAL EXHAUST SUFFICIENT TO
KEEP ALL HAZARDOUS VAPOR CONCS BELOW PRESCRIBED LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: ACRYLIC FLAT FINISH. EXPLAN OF CARCIN: REPORT
ON CARCINOGENS, 1994:ANTICIPATED TO BE CARCINOGEN. RESP PROT: WEAR
A SUITABLE, PROPERLY FITTED NIOSH APPRVD RESP (TC-23C OR BETT ER)
FOR ORGANIC VAPORS W/DUST FILTER ASNEEDED.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGS
Vapor Density:LTR/AIR
Spec Gravity:1.32-1.44
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:55-60
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:MAY PRODUCE HAZARDOUS FUMES WHEN
HEATED TO DECOMPOSITION AS IN WELDING.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISCARD IN LAND FILL IN SEALED METAL CONTAINERS
AWAY FROM HEAT AND FLAME AND IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.